C2 Paired Compässo™ Channel Accents
-
Allowing the creation of unique way-finding, these multi-functional ceiling accents combine both form and function.They are ideal for retail spaces, contemporary offices, entertainment facilities, gaming establishments and education environments.
C2 Paired Compässo™ channel accents are multi-functional design elements that easily integrate lighting and signage. They can be used as way-finding devices throughout a space, delivering a great surface for applied graphics and signage.
The channels compliment existing ceilings or open plans without ceilings. They install easily without field cutting and can be suspended from the ceiling with hanger wire, cable, or rods. They are available in an unlimited combination of straight and curved pieces, which allow you to create unique configurations using circles, straight pieces, curves, arcs and angles.
| Title | Size | Add to Submittal |
|---|---|---|
| C2 Paired Compasso Channels Architectural Spec - 09581-09543610 [MSW8] | 66 KB |
|
| Title | Size | Add to Submittal |
|---|---|---|
| C2 Paired Compässo™ Channels Data/Submittal Sheet (English) - IC401 [PDF] | 287 KB |
|
| Title | Size | Add to Submittal |
|---|---|---|
| C2 Paired Compässo™ Channels Installation Guide - IC412 [PDF] | 1,159 KB |
|
| Exposed Hanger Solutions Installation Guide - IC453 [PDF] | 68 KB |
|
| Title | Size | Add to Submittal |
|---|---|---|
| Ceiling Systems Catalog Supplement - SC2000A [PDF] | 29,752 KB |
|
| USG Compässo™ Trim and C2 Paired Channels Brochure - IC400 [PDF] | 775 KB |
|
| Title | Size | Add to Submittal |
|---|---|---|
| Seismic Technical Guide - Specialty and Decorative Ceilings (English) - SC2494 [PDF] | 154 KB |
|
| Seismic Technical Guide - Specialty and Decorative Ceilings (Spanish) - SC2494SP [PDF] | 179 KB |
|
| Title | Size | Add to Submittal |
|---|---|---|
| DONN® Ceilings Warranty - SC2102 [PDF] | 92 KB |
|
General
Q: Does COMPÄSSO™ come in heights greater than 8 inches?
A: Yes. COMPÄSSO is available in 2 1/4 inches, 4 inches, 6 inches, 8 inches, 10 inches and 12 inches
Distribution and Handling
Q: Will the panels bend if handled incorrectly?
A: Yes. Handle panels in such a manner as to ensure against racking, distorti on or physical damage of any kind.
Q: How should I store my specialty panels?
A: Store panels in a manner that will prevent scratches or damage of any kind.
Q: Should the materials be opened immediately after delivery?
A: No. However, you should check to make sure you received everything listed in the Bill of Materials. Inspect the packaging for damage.
Q: Will the panels bend if handled incorrectly?
A: Yes. Handle panels in such a manner as to ensure against racking, distortion or physical damage of any kind.
Q: How should I store my specialty panels?
A: Store panels in a manner that will prevent scratches or damage of any kind.
Installation
Q: Do I have to cut COMPÄSSO™ to fit at the job site?
A: No. COMPÄSSO is pre-engineered in the factory for fast installation and repeatable quality.
Q: How do you take main tees apart without a tool?
A: Facing the main tee splice place your left hand near the left side of the splice and right hand near the right side of the splice. Using a shearing motion, push with your left hand and pull with your right hand. This disconnects the main tee splice. Be sure to straighten the end tabs before attempting to reconnect.
Q: How much force is required to insert a cross tee with a quick release clip?
A: It takes 12-14 pounds of force to install a cross tee.
Q: How is the spacing of wire hangers determined for fire-rated assemblies?
A: All systems must be installed and tested in compliance with ASTM C636.
Q: What gauge hanger wire is needed to install grid?
A: For residential installation 18-gauge wire is required. For commercial installation 12-gauge wire is required.
Q: Do you mechanically attach the SHEETROCK ® Brand Liner Panels to the USG H studs?
A: No. The panels just slide into place.
Q: How do you remove cross tees without a tool?
A: To remove a cross tee, push up on the main tee with your thumbs (where the cross tee is connected) and rotate it until the cross tee pops up and out of the slot.
Q: What is the best way to suspend a ceiling system beneath an existing grid system?
A: What is the best way to suspend a ceiling system beneath an existing grid system?
Q: How far apart should hanger wires be spaced when installing grid?
A: Hanger wires should be spaced between 4' and 6' depending on how much load the grid will carry. Hanger wires that are spaced closer allow the system to carry heavier loads.
Performance
Q: What is the warranty for a system, that uses USG tile and grid together?
A: There is a lifetime warranty on any ceiling system that is used in conjunction with our tile and grid. All grid is lifetime when used with USG tile, however not all tile is lifetime when used with USG grid. See complete warranty for details.
Q: What are the best grids to use in an area that is accessible to moisture?
A: DONN ® AX™ or ZXLA™.
Q: Which grid is the best grid to use in a Clean Room environment?
A: DONN ® CE is the best grid for a Clean Room environment.
Q: What is the standard warranty of grid?
A: Ten years. See complete warranty for details.
Technical
Q: When installing grid, what is the minimum clearance needed from the overhead structure?
A: Minimum clearance is 3", which allows ceiling tiles to be inserted and removed freely
Q: How is the load test data collected for ceiling grid?
A: Load data and spans are based on simple span tests in accordance with ASTM C635, with a deflection limitation of L/360.
| Product Name |
|---|
| Compässo™ Suspension Trim |
Global Websites