DONN® CE™ Acoustical Suspension System
-
Offering a particulate-free sealed ceiling system, this system is ideal for hospitals. Its hot-dipped galvanized and painted steel body provides unequaled corrosion protection.
The DONN CE (Controlled Environment) acoustical suspension system features an exposed grid system, with a factory-applied gasket and a 15/16" or 1-1/2" face for rooms that require a clean, particulate-free, sealed ceiling system. With positive isolation from the plenum above, it is certified for Class 100 clean room environment per Federal Standard 209(e). (ISO Level 5)
DONN acoustical and drywall suspension systems have the highest average recycled content in the industry. In fact, many of the components are available with High Recycled Content (HRC). HRC suspension components are classified as containing over fifty percent total recycled content. Total recycled content is based on product composition of post-consumer and pre-consumer (post-industrial) recycled content per FTC guidelines. Look for the green symbol on data pages to quickly identify HRC components.
With all the design and installation advantages of the DX® system, CE provides the load carrying capacity needed for ceiling panels, light fixtures and HVAC components, including H.E.P.A. filters.
Its patented Quick-Release™ cross tees are easy to remove without tools, decreasing renovation costs. They have offset ends that rest on the main tees for better appearance (no exposed edges) without sagging or twisting, and they cantilever during installation and withstand dropping out.
Corrosion resistant, stainless steel locking tee ends provide pull-out tension values in excess of 200 lbs. Punched with cross tee holes and hanger wire holes at 6" o.c., they allow for maximum installation flexibility. Optional US28CE perimeter detail provides improved air seal at walls.
Factory-applied closed cell foam gaskets eliminate labor-intensive field application. The system meets or exceeds all national code requirements, including seismic; and meets or exceeds load compliance specifications per ASTM C635.
Available in Flat White.
| Title | Size | Add to Submittal |
|---|---|---|
| DONN® Suspension Systems Brochure - AC3163 [PDF] | 268 KB |
|
| Title | Size | Add to Submittal |
|---|---|---|
| Seismic Certification of Performance (English) - AC3235 [PDF] | 1,022 KB |
|
| Seismic Certification of Performance (Spanish) - AC3235SP [PDF] | 1,040 KB |
|
| Title | Size | Add to Submittal |
|---|---|---|
| DONN® Suspended Ceiling Installation Guide - R38 [PDF] | 815 KB |
|
| Title | Size | Add to Submittal |
|---|---|---|
| DONN® Suspension System CE MSDS (English) - 42-100-004 [PDF] | 127 KB |
|
| DONN® Suspension System CE MSDS (French) - 42-100-004 [PDF] | 132 KB |
|
| DONN® Suspension System CE MSDS (Spanish) - 42-100-004 [PDF] | 133 KB |
|
| Title | Size | Add to Submittal |
|---|---|---|
| Ceiling Systems Catalog - SC2000 [PDF] | 42,936 KB |
|
| Ceiling Systems Catalog Supplement - SC2000A [PDF] | 29,752 KB |
|
| DONN® Suspension Systems System Catalog - SA904 [PDF] | 238 KB |
|
| Title | Size | Add to Submittal |
|---|---|---|
| DONN® Ceilings Warranty - SC2102 [PDF] | 92 KB |
|
Installation
Q: How much force is required to insert a cross tee with a quick release clip?
A: It takes 12-14 pounds of force to install a cross tee.
Q: What is the best way to suspend a ceiling system beneath an existing grid system?
A: What is the best way to suspend a ceiling system beneath an existing grid system?
Q: How do you remove cross tees without a tool?
A: To remove a cross tee, push up on the main tee with your thumbs (where the cross tee is connected) and rotate it until the cross tee pops up and out of the slot.
Q: Do you mechanically attach the SHEETROCK ® Brand Liner Panels to the USG H studs?
A: No. The panels just slide into place.
Q: How do you take main tees apart without a tool?
A: Facing the main tee splice place your left hand near the left side of the splice and right hand near the right side of the splice. Using a shearing motion, push with your left hand and pull with your right hand. This disconnects the main tee splice. Be sure to straighten the end tabs before attempting to reconnect.
Q: What gauge hanger wire is needed to install grid?
A: For residential installation 18-gauge wire is required. For commercial installation 12-gauge wire is required.
Q: How is the spacing of wire hangers determined for fire-rated assemblies?
A: All systems must be installed and tested in compliance with ASTM C636.
Q: How far apart should hanger wires be spaced when installing grid?
A: Hanger wires should be spaced between 4' and 6' depending on how much load the grid will carry. Hanger wires that are spaced closer allow the system to carry heavier loads.
Performance
Q: What is the standard warranty of grid?
A: Ten years. See complete warranty for details.
Q: Which grid is the best grid to use in a Clean Room environment?
A: DONN ® CE is the best grid for a Clean Room environment.
Q: What is the warranty for a system, that uses USG tile and grid together?
A: There is a lifetime warranty on any ceiling system that is used in conjunction with our tile and grid. All grid is lifetime when used with USG tile, however not all tile is lifetime when used with USG grid. See complete warranty for details.
Q: What are the best grids to use in an area that is accessible to moisture?
A: DONN ® AX™ or ZXLA™.
Technical
Q: How is the load test data collected for ceiling grid?
A: Load data and spans are based on simple span tests in accordance with ASTM C635, with a deflection limitation of L/360.
Q: When installing grid, what is the minimum clearance needed from the overhead structure?
A: Minimum clearance is 3", which allows ceiling tiles to be inserted and removed freely
Additional Resources

Quick Facts
- Fire Class A
- Colors: [Flat White 050]
- Edge/Profile: [CE - Controlled Environment 1-1/2" (Gasketed)]
- Humidity Resistant
- 60% Recycled