UL W460

Exterior Walls - Steel Stud (Load-Bearing)

Fire Rating 3 hours
System STC n/a
System Thickness 7 1/4 in.

CAD/Revit & Acoustics

Assembly Construction

Assembly Construction

Layer 1 - Floor/Ceiling Runners:

Channel-Shaped, 3-1/2" min. wide with 1-1/2" min. legs, fabricated from No. 20 GA. Min. (0.0329" min. Bare Metal Thickness) Corrosion Resistant Steel. Attached to floor and ceiling with steel fasteners spaced not greater than 24"

Layer 2 - Gypsum Board:

5/8" Thick Gypsum Panel (UL Type USGX)

Layer 3 - Steel Studs:

3-1/2" [89 mm] steel studs, 20 ga. (0.033"), 24" [610 mm] O.C.

Layer 4 - Insulation:

3-1/2" Glass Fiber Batt Insulation (Optional)

Layer 5 - Lateral Support Members:

Where required for lateral support of Studs, support may be provided by means of Steel Straps, Channels or other similar means as specified in the design of a particular Steel Stud Wall System (not shown)

Layer 6 - Gypsum Board:

5/8" Thick Gypsum Panel (UL Type SCX)

Notes

  1. For the most up-to-date details, including construction variations, refer to the published assembly in the UL Product IQ™ database or GA Design Manual.
  2. Stud sizes and insulation thickness are minimum unless otherwise stated in the published assembly.
  3. Stud and fastener spacings are maximum unless otherwise stated in the published assembly.
  4. Panel orientation shall be as specified in the published assembly.
  5. Refer to applicable codes requirements to ensure compliance prior to construction.
  6. Where acoustical performance is provided in an estimated range, the values are based on laboratory test data of similarly constructed assemblies.
  7. Where design no. indicates “per”, the fire rating is based on laboratory test data of the referenced similarly constructed assemblies.