Change your country/region

It looks like you entered an employee email address, but this is the customer sign-in. Use the link below instead.

Explore Sizes & Options

Item: R76775

Acoustics: 0.70 NRC / 35 CAC

Size: 2 ft. x 2 ft.

Edge: Shadowline Tapered

Color: White

Overview

Overview

With ClimaPlus™ Performance
Available in Retail Only

Superior sound and sag control with high light reflectance values. Luna™ Acoustical Panels are durable acoustical panels perfect for small stores, boutiques, reception areas, home offices and entertainment rooms.

Main Features

Luna™ Acoustical Panels are manufactured for maximizing sound and anti-sag performance. High light reflectance values translates to fewer light fixtures and lower energy costs. And these panels feature superior performance an antimicrobial formulation that inhibits mold and mildew growth.
  • High light reflectance minimizes eyestrain and energy costs
  • Absorb and block sound for high total sound control
  • Clean easily with soft brush or vacuum
  • Low VOC-emitting panels
  • ClimaPlus™ 30-year lifetime system warranty

Applications

  • Administrative Offices
  • Classrooms
  • Convention and Meeting Rooms
  • Department Stores and Boutiques
  • Executive Areas, Conference Areas and Board Rooms
  • Galleries and Exhibit Spaces
  • Guest Rooms and Suites
  • Lobbies and Reception Areas
  • Mall Interior Spaces
  • Media Centers, Music Rooms and Libraries
  • Nurseries and Birthing Rooms
  • Patient Rooms

Specifications

Data Sheet PDF 5.2 MB

Performance

  • Sound Absorption (NRC)
    NRC stands for Noise Reduction Coefficient. It is a measure of how much sound is absorbed by a given material. It is listed as a decimal and relates to percentage sound absorbed.
    0.70
  • Sound Attenuation (CAC) 35
  • Light Reflectance 0.86
  • Mold & Mildew Resistance Yes
  • Fire Resistance
    • Fire Rating Class A
  • ASTM E1264
    • astm-e1264-class III: Mineral base with painted finish, E: Lightly textured; I: Embossed, Form 1: Nodular
  • ASTM E84
    • Flame Spread 25
    • Smoke Developed 50
    • Fire Rating Class A

Sustainability

  • GREENGUARD Certification Yes
  • Recycled Content 77.9%
  • VOC Emissions Low-emitting

Physical Data

  • Thickness (in.) 3/4
  • Color White
  • Edge Shadowline Tapered
  • Panel Size 2 ft. x 2 ft.
  • Material Mineral Fiber

Documents & Files

Data Sheets & Specifications

Data/Submittal Sheet (English) PDF 5.2 MB

Catalogs & Brochures

System Catalog (English) PDF 12.7 MB

SDS, Certifications & Reports

SDS (English) PDF 191.4 KB
SDS (Spanish) PDF 193.8 KB
Certificates (English) PDF 1.1 MB

Ask a question

Our customer support team will get back to you as soon as possible.

Question Guidlines

  • Questions should relate to this product specifically.
  • For help with pricing, availability, or delivery, please call 800.874.4968 (Monday–Friday, 7am–6pm Central)
  • All questions and answers follow USG’s Terms & Conditions.
  • Your question and USG’s answer may be posted to this page in the future, but none of your personal info will be included.

 Thanks for your message. We’ll be in touch!

q & a

  • Why is LR important?

    When the proper type of lighting fixture is used with a high LR ceiling, there can be savings in both initial construction costs as well as long-term energy costs. The concept is to use the ceiling to reflect light back into the occupied space.

  • Why is NRC important?

    NRC is very important in open office plan environments where there are few full height walls to help absorb or block sound.

  • What does ClimaPlus™ mean?

    USG’s line of products with ClimaPlus™ Performance have additional resistance to temperature and humidity. This in turn provides additional resistance to sagging and warping of the ceiling panels.

  • What does LR stand for?

    LR stands for light reflectance. It is a measure of the percentage of light which is reflected off of a given panel surface. Typically, the whiter and smoother the ceiling panel, the higher the LR value.

  • What is NRC?

    NRC stands for Noise Reduction Coefficient. It is a measure of how much sound is absorbed by a given material. It is listed as a decimal and relates to percentage sound absorbed.

  • When referring to ceiling panels, what is the meaning of type, form and pattern?

    These categories refer to ASTM Test E 1264.
    Type refers to the base material of the panel.
    Form refers to the manufacturing process of the panel.
    Pattern refers to the type of texture or pattern in the panel.

  • What is the difference between Class A and Firecode® branded materials?

    Class A signifies that a panel attained a flame spread index of 25 or less (based on 100 for untreated red oak) when tested in accordance with the Standard ASTM E 84. The Firecode® brand signifies that the panel has been classified as a protective membrane in a floor-ceiling or roof-ceiling assembly in accordance with the Standard ASTM E 119. All Firecode® protective membranes offered by USG have attained a Class A rating.

  • When hold-down clips are required, how much space should I leave between the clips, on the grid?

    The recommendation for hold-down clip spacing is two clips per panel, centered on the grid, between the panels.

  • How many acoustical panel types does USG offer?

    USG offers four major types of acoustical panels as well as Gypsum based panels for special applications. They are: Wet-Felted, Cast, "X" Technology and Fiberglass.

  • What is the best way to cut a reveal in a ceiling panel?

    The best way to cut a reveal edge in a panel is with a utility knife or a special Reveal edge tool.

  • How far in advance can I order ceiling panel before installation?

    Storage time of materials at the job site should be as short as possible, and environmental conditions should be as near as possible to those specified for occupancy. Excess humidity during storage can cause expansion of material and possible warp, sag, or poor fit after installation. Chemical changes in the mat and/or coatings can be aggravated by excess humidity and cause discoloration during storage, even in unopened cartons. Cartons should be removed from pallets and stringers to prevent distortion of material. Long-term (6-12 months) storage under uncontrolled environmental conditions should be avoided.

  • What is the minimum NRC recommended for open office plan environments?

    It is best to use a minimum of .70 NRC and up to .80 - .90 NRC panel for this type of application.

  • What is "X" Technology?

    "X" Technology is a unique manufacturing method which was developed by and introduced to the market by USG in 1989. This technology is used to produce ceiling panels with sag resistance and exceptional acoustical performance found in USG’s line of ceiling products with ClimaPlus™ Performance.

  • What is CAC?

    CAC stands for Ceiling Attenuation Class. It is the measure of the blocking of sound through one ceiling plane, into the plenum above, and back through the other ceiling plane to an adjacent space.

  • Why would I use one ceiling panel type over another?

    The different panel substrates provide panels with unique characteristics. The use of the different panels will vary based on specific needs and application.

  • Have a question?

    Let us do the research. We'll get back to you as quickly as we can.

    Ask USG
  • Need help right away?

    Call our Technical Support team at 800-874-4968 (Monday-Friday, 7:30 am - 4 pm Central).

Top