Change your country/region

It looks like you entered an employee email address, but this is the customer sign-in. Use the link below instead.

UL G556

Steel C-Joist (Load-Bearing)

Fire Rating 2 hours
System STC n/a
System IIC n/a
System Thickness Varies

CAD/Revit & Acoustics

Assembly Construction

Assembly Construction

Layer 1 - Subfloor Topping Mixture:

1 layer 3/4" Thick Levelrock® Brand 4500 Series Floor Underlayments

Layer 2 - Sound Mat (Optional):

1 layer 1/4" Thick Levelrock® Brand SRM-25™ Ready Seam™ Sound Reduction Mat

Layer 3 - Structural Cement-Fiber Units:

1 layer 3/4" Thick, USG Structural Panel Concrete Subfloor (USGSP), with long edges tongue and grooved, long dimension of panels to be perpendicular to Joists (UL Type USGSP)

Layer 4 - Steel Joists:

1 layer Channel-Shaped, 10" Deep Min., 16 Ga., Spaced 24" Max. O.C.

Layer 5 - Clip Angles (Not Shown):

1 layer One Clip Angle Per Joist End; One Clip Angle per Joist End

Layer 6 - Joist Bridging (Not Shown):

1 layer V-Bracing of 1-1/2", 20 Ga., Galvanized Steel Between Channels

Layer 7 - Insulation:

1 layer 3-5/8" Thick Glass Fiber Batt Insulation

Layer 8 - Steel Framing Members:

1 layer Suspension System May be Used in Lieu of the Resilient Channels. Main Runners, Cross Tees, Cross Channels and Wall Angle as Listed Below (UL Type DGL):; Suspension System May be Used in Lieu of the Resilient Channels. Main Runners, Cross Tees, Cross Channels and Wall Angle as Listed Below (UL Type DGL):

Layer 9 - Main Runners:

1 layer 4' O.C. Main Runners Suspended by 12 ga. Min. Hanger Wire, 16" O.C.

Layer 10 - Cross Tees:

1 layer 16" O.C.

Layer 11 - Cross Channels:

1 layer 16" O.C.

Layer 12 - Wall Angle or Channel:

1 layer Painted or Galvanized Steel Angle to Support Steel Framing Member Ends and for Screw-Attachment of the Gypsum Panel (UL Type DGL)

Layer 13 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX™)

Notes