UL W460

Exterior Walls - Steel Stud (Load-Bearing)

Fire Rating 3 hours
System STC n/a
System Thickness 7 1/4 in.

CAD/Revit & Acoustics

Assembly Construction

Assembly Construction

Layer 1 - Floor/Ceiling Runners:

Channel-Shaped, 3-1/2" min. wide with 1-1/2" min. legs, fabricated from No. 20 GA. Min. (0.0329" min. Bare Metal Thickness) Corrosion Resistant Steel. Attached to floor and ceiling with steel fasteners spaced not greater than 24"

Layer 2 - Gypsum Board:

5/8" Thick Gypsum Panel (UL Type USGX)

Layer 3 - Steel Studs:

3-1/2" [89 mm] steel studs, 20 ga. (0.033"), 24" [610 mm] O.C.

Layer 4 - Insulation:

3-1/2" Glass Fiber Batt Insulation (Optional)

Layer 5 - Lateral Support Members:

Where required for lateral support of Studs, support may be provided by means of Steel Straps, Channels or other similar means as specified in the design of a particular Steel Stud Wall System (not shown)

Layer 6 - Gypsum Board:

5/8" Thick Gypsum Panel (UL Type SCX)

Notes