UL U493

Chase Wall - Steel Stud (Non-Load-Bearing)

Fire Rating 2 hours
System STC 65
System Thickness 10.75 in.

CAD/Revit & Acoustics

Assembly Construction

Assembly Construction

Layer 1 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® Gypsum Panel (UL Type SCX)

Layer 2 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® Gypsum Panel (UL Type SCX)

Layer 3 - Steel Studs:

1 layer 3-5/8" [92 mm] steel studs, EQ20 (0.018"), staggered, 16" [406 mm] O.C.

Layer 4 - Insulation:

1 layer 3-1/2" [89 mm] Fiberglass insulation

Layer 5 - Air Space:

1 layer 1" [25.4 mm] air space

Layer 6 - Steel Studs:

1 layer 3-5/8" [92 mm] steel studs, EQ20 (0.018"), staggered, 16" [406 mm] O.C.

Layer 7 - Insulation:

1 layer 3-1/2" [89 mm] Fiberglass insulation

Layer 8 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® Gypsum Panel (UL Type SCX)

Layer 9 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® Gypsum Panel (UL Type SCX)

Notes