UL U419

Interior Partition - Steel Stud (Non-Load-Bearing)

Fire Rating 1 hours
System STC 50
System Thickness 5.375 in.

CAD/Revit & Acoustics

Assembly Construction

Assembly Construction

Layer 1 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX™)

Layer 2 - Resilient Channel:

1 layer 1/2" [12.7 mm] resilient channel, 25 ga. (0.018"), 24" [610 mm] O.C.

Layer 3 - Steel Studs:

1 layer 3-5/8" [92 mm] steel studs, EQ20 (0.018"), 24" [610 mm] O.C.

Layer 4 - Insulation:

1 layer 3-1/2" [89 mm] Fiberglass insulation

Layer 5 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX™)

Notes