UL U419

Interior Partition - Steel Stud (Non-Load-Bearing)

Fire Rating 3 hours
System STC 55
System Thickness 7.375 in.

CAD/Revit & Acoustics

Assembly Construction

Assembly Construction

Layer 1 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX™)

Layer 2 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX™)

Layer 3 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX™)

Layer 4 - Steel Studs:

1 layer 3-5/8" [92 mm] steel studs, EQ20 (0.018"), 24" [610 mm] O.C.

Layer 5 - Insulation:

1 layer 3-1/2" [89 mm] Fiberglass insulation

Layer 6 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX™)

Layer 7 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX™)

Layer 8 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX™)

Notes