Change your country/region

It looks like you entered an employee email address, but this is the customer sign-in. Use the link below instead.

GA WP 4232

Chase Wall - Wood Stud (Load-Bearing)

Fire Rating 2 hours
System STC 60
System Thickness 11.75 in.

CAD/Revit & Acoustics

Assembly Construction

Assembly Construction

Layer 1 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® Gypsum Panel (UL Type SCX)

Layer 2 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® Gypsum Panel (UL Type SCX)

Layer 3 - Wood Studs:

1 layer 2" x 4" [38 x 89 mm] Wood Studs, 24" [610 mm] O.C.

Layer 4 - Insulation:

1 layer 3-1/2" [89 mm] Fiberglass insulation

Layer 5 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® Gypsum Panel (UL Type SCX)

Layer 6 - Air Space:

1 layer 1" [25.4 mm] air space

Layer 7 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® Gypsum Panel (UL Type SCX)

Layer 8 - Wood Studs:

1 layer 2" x 4" [38 x 89 mm] Wood Studs, 24" [610 mm] O.C.

Layer 9 - Insulation:

1 layer 3-1/2" [89 mm] Fiberglass insulation

Layer 10 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® Gypsum Panel (UL Type SCX)

Layer 11 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® Gypsum Panel (UL Type SCX)

Notes