Change your country/region

It looks like you entered an employee email address, but this is the customer sign-in. Use the link below instead.

UL U407

Interior Partition - Wood Stud (Load-Bearing)

Fire Rating 0.5 hours
System STC 45
System Thickness 5.25 in.

CAD/Revit & Acoustics

Assembly Construction

Assembly Construction

Layer 1 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® Ecosmart Firecode 30® Gypsum Panel (UL Type FC30)

Layer 2 - Wood Studs:

1 layer 2" x 4" [38 x 89 mm] Wood Studs, 16" [406 mm] O.C.

Layer 3 - Insulation:

1 layer 3-1/2" [89 mm] Fiberglass insulation

Layer 4 - Resilient Channel:

1 layer 1/2" [12.7 mm] resilient channel, 25 ga. (0.018"), 24" [610 mm] O.C.

Layer 5 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® Ecosmart Firecode 30® Gypsum Panel (UL Type FC30)

Notes