Change your country/region

It looks like you entered an employee email address, but this is the customer sign-in. Use the link below instead.

Item: 143133

Sheetrock® Brand Mold Tough® Ultracode® Core Panels

3/4 in. (19.1 mm) Type X panels with moisture and mold resistance that reduce labor and material costs

Available Product Options

Thickness: 3/4 in.

Width: 48 in.

Order a Sample

Overview

Overview

Sheetrock® Brand Mold Tough® Ultracode® Core Panels (UL Type ULTRACODE) are 3/4 in. (19.1 mm) Type X panels that can provide 1-4 hr. fire ratings with fewer layers of gypsum panels than are typically required when used in approved applications. These enhanced fire-resistant gypsum panels feature a noncombustible, moisture-resistant gypsum core that is encased in moisture-and mold-resistant, 100% recycled green face and brown back papers. When tested in accordance with ASTM D3273, Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber, the panels meet or exceed ASTM C1396 specifications. The face paper is folded around the long edges to reinforce and protect the core, and the ends are cut square and even. The long edges of the panels are tapered, allowing joints to be reinforced and concealed with Sheetrock® Brand joint treatment systems. The panels are UL Classified for fire resistance and can be used in any UL Design in which Type ULTRACODE panels are listed. On the face, along the long edge of each panel, the UL Type Designation is printed for easy identification by building inspectors.

Main Features

  • 3/4 in. (19.1 mm) Type X panels with moisture and mold resistance that reduce labor and material costs
  • Feature a noncombustible, moisture-resistant gypsum core encased in moisture- and mold-resistant, 100% recycled green face and brown back papers
  • Can provide 1-4 hr. fire ratings with fewer layers of gypsum panels than are typically required when used in approved applications
  • Comply with ASTM C1396, Standard Specification for Gypsum Board, for 3/4 in. (19.1 mm), Type X and water-resistant gypsum wallboard
  • When tested in accordance with ASTM D3273, Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber, the panels meet or exceed ASTM C1396 specifications
  • Underwriters Laboratories Inc. (UL) Classification as to fire resistance, surface-burning characteristics and noncombustibility
  • Achieved GREENGUARD Gold Certification and qualifies as a low VOC emitting material (meets CA 01350)

Applications

  • Corridors and Hallways
  • Dormitories
  • Health and Fitness
  • Kitchens and Food Prep Areas
  • Nurseries and Birthing Rooms
  • Restrooms, Utility Rooms and Loading Docks
  • Traditional Offices

Specifications

Submittal Sheet PDF 399.9 KB

Performance

  • Mold & Mildew Resistance Yes
  • Fire Resistance
    • Fire Rating Type X
  • ASTM E84
    • Flame Spread 15
    • Smoke Developed 0
    • Fire Rating Type X
  • ASTM Type ASTM C1396; ASTM C473; ASTM D3273; ASTM E136; ASTM E84
    • Flame Spread 15
    • Smoke Developed 0
    • Fire Rating Type X
  • UL Type Designations ULTRACODE

Sustainability

  • GREENGUARD Certification Yes

Physical Data

  • Thickness (in.) 3/4
  • Edge Tapered Edge
  • Panel Size 48 in. x 8-12 ft.
  • Nominal Weight 2.8 lb./sq. ft.

Documents & Files

Data Sheets & Specifications

Data/Submittal Sheet (English) PDF 399.9 KB
Architectural Specification (English) DOCX 129.2 KB

White Papers

White Paper (English) PDF 729.3 KB

Installation & Technical Manuals

Technical Guide (English) PDF 115.3 KB
Installation Guide (English)

SDS, Certifications & Reports

SDS (English) PDF 160.6 KB
SDS (Spanish) PDF 151.3 KB

Ask a question

Our customer support team will get back to you as soon as possible.

Question Guidlines

  • Questions should relate to this product specifically.
  • For help with pricing, availability, or delivery, please call 800.874.4968 (Monday–Friday, 7am–6pm Central)
  • All questions and answers follow USG’s Terms & Conditions.
  • Your question and USG’s answer may be posted to this page in the future, but none of your personal info will be included.

 Thanks for your message. We’ll be in touch!

q & a

  • What is the maximum spacing allowed between gypsum panels over framing?

    The maximum space allowed between panels is 1/8 of an inch. Any space larger can lead to problems with joint finishing cracking.

  • Can gypsum panels be installed horizontally?

    Gypsum panels can be installed horizontally or vertically. Installing the board horizontally lessens the total amounts of joints to be taped by 25%.

  • Can I store Sheetrock® Brand Gypsum Panels outside?

    Sheetrock® Brand Gypsum Panels must be protected from exposure to excessive or continuous moisture and the elements before, during and after installation. Storing outdoors uncovered is not recommended.

  • What is the recommended fastener spacing for attaching gypsum panels to walls and ceilings in non-fire-rated assemblies?

    When nailing to wood construction the spacing is 7 inches for ceilings, and 8 inches for walls. When screwing into wood and steel framing the spacing is 12 inches on ceilings and 16 inches for walls. Refer to the relevant fire test to determine fastener type and spacing.

  • What is the recommended spacing of control joints for gypsum panels for walls and ceilings?

    The maximum recommended control joint spacing for walls and ceilings without perimeter relief is 30 feet. With perimeter relief the maximum recommended control joint spacing is 50 feet.

  • What is the recommended application for fastening gypsum panels to walls and ceilings?

    When nailing to wood construction the spacing is 7 inches for ceilings, and 8 inches for walls. When screwing into wood and steel framing the spacing is 12 inches on ceilings and 16 inches for walls. Refer to the relevant fire test to determine fastener type and spacing.

  • When hanging gypsum panels on the ceiling should the board be applied parallel or perpendicular?

    Half-inch panels must be applied perpendicular and 5/8 inches can be applied either way.

  • Have a question?

    Let us do the research. We'll get back to you as quickly as we can.

    Ask USG
  • Need help right away?

    Call our Technical Support team at 800-874-4968 (Monday-Friday, 7:30 am - 4 pm Central).

Top