Change your country/region

It looks like you entered an employee email address, but this is the customer sign-in. Use the link below instead.

USG Radar™ Acoustical Panels with ClimaPlus™ Performance, and USG Donn® Brand DX® Acoustical Suspension System
USG Radar™ Acoustical Panels with ClimaPlus™ Performance
USG Radar™ Acoustical Panels with ClimaPlus™ Performance, and USG Donn® Brand DX® Acoustical Suspension System
Item: 2235

Radar™ Firecode® Acoustical Panels

Lightly textured panels. High-durability, non-directional pattern panels are 55% more durable than standard panels and include Firecode® for meet life-safety codes.

Explore Sizes & Options

Item: 2235

Acoustics: 0.55 NRC / 35 CAC

Size: 2 ft. x 2 ft.

Edge: Fineline Bevel

Color: White

Standard Colors

Overview

Overview

With ClimaPlus™ Performance
Designed with an excellent resistance to mold and mildew, these medium textured panels offer a clean, fresh look. Radar™ Firecode® Acoustical Ceiling Panels contain a proprietary broad-spectrum standard formulation that inhibits the growth of mold and mildew. Medium textured with a non-directional pattern, these sag resistant panels are an optimal choice for use in schools, corridors, lobbies, offices and retail stores.

Main Features

Radar™ Firecode® Acoustical Ceiling Panels offer the best in IEQ, and install quickly and efficiently.
  • Non-directional pattern
  • ClimaPlus™ 30-year lifetime system warranty against visible sag, mold and mildew
  • Firecode® product designed to meet life-safety codes
  • USDA Certified Biobased Product
  • Low-emitting product meets CA Specification 01350, California Department of Health Services Standard Practice for the testing of VOC emissions
  • Available with High Recycled Content (HRC)

Applications

  • Administrative Offices
  • Cafeterias
  • Classrooms
  • Corridors and Hallways
  • Department Stores and Boutiques
  • Grocery Stores
  • Health and Fitness
  • Mechanical Rooms
  • Patient Rooms
  • Restrooms, Utility Rooms and Loading Docks
  • Stairways and Elevator Shafts
  • Warehouses

Specifications

Data Sheet

Performance

  • Sound Absorption (NRC)
    NRC stands for Noise Reduction Coefficient. It is a measure of how much sound is absorbed by a given material. It is listed as a decimal and relates to percentage sound absorbed.
    0.55
  • Sound Attenuation (CAC) 35
  • Light Reflectance 0.84
  • Mold & Mildew Resistance Yes
  • Fire Resistance
    • Fire Rating Firecode®
  • ASTM E1264
    • astm-e1264-class III: Mineral base with painted finish, C: Perforated, small holes; D: Fissured; E: Lightly textured, Form 2: Water-Felted
  • ASTM E84
    • Flame Spread 25 or less
    • Smoke Developed 50 or less
    • Fire Rating Firecode®

Sustainability

  • GREENGUARD Certification Yes
  • Recycled Content 51-59%
  • VOC Emissions Low-emitting
  • Bio Based Yes

Physical Data

  • Thickness (in.) 5/8
  • Color White
  • Edge Fineline Bevel
  • Panel Size 2 ft. x 2 ft.
  • Material Mineral Fiber

Installation

Installation Guide PDF 822.1 KB

play

USG Ceilings Portfolio Series: Episode 1 - Installation & Edge Style

play

USG Ceilings Portfolio Series: Episode 2 - Performance Features

play

USG Ceilings Portfolio Series: Episode 3 - USG Panel Types

Documents & Files

Data Sheets & Specifications

Data/Submittal Sheet (English)

Catalogs & Brochures

System Catalog (English) PDF 45.2 MB
Brochure (English) PDF 186.1 KB

Installation & Technical Manuals

Technical Guide (English)
Installation Guide (English) PDF 822.1 KB

SDS, Certifications & Reports

SDS (Spanish) PDF 236.7 KB
Certificates (English) PDF 500.2 KB

Warranties

Warranties (English) PDF 147.7 KB

Ask a question

Our customer support team will get back to you as soon as possible.

Question Guidlines

  • Questions should relate to this product specifically.
  • For help with pricing, availability, or delivery, please call 800.874.4968 (Monday–Friday, 7am–6pm Central)
  • All questions and answers follow USG’s Terms & Conditions.
  • Your question and USG’s answer may be posted to this page in the future, but none of your personal info will be included.

 Thanks for your message. We’ll be in touch!

q & a

  • Why is LR important?

    When the proper type of lighting fixture is used with a high LR ceiling, there can be savings in both initial construction costs as well as long-term energy costs. The concept is to use the ceiling to reflect light back into the occupied space.

  • What does ClimaPlus™ mean?

    USG’s line of products with ClimaPlus™ Performance have additional resistance to temperature and humidity. This in turn provides additional resistance to sagging and warping of the ceiling panels.

  • What does LR stand for?

    LR stands for light reflectance. It is a measure of the percentage of light which is reflected off of a given panel surface. Typically, the whiter and smoother the ceiling panel, the higher the LR value.

  • What is NRC?

    NRC stands for Noise Reduction Coefficient. It is a measure of how much sound is absorbed by a given material. It is listed as a decimal and relates to percentage sound absorbed.

  • When referring to ceiling panels, what is the meaning of type, form and pattern?

    These categories refer to ASTM Test E 1264.
    Type refers to the base material of the panel.
    Form refers to the manufacturing process of the panel.
    Pattern refers to the type of texture or pattern in the panel.

  • What is the difference between Class A and Firecode® branded materials?

    Class A signifies that a panel attained a flame spread index of 25 or less (based on 100 for untreated red oak) when tested in accordance with the Standard ASTM E 84. The Firecode® brand signifies that the panel has been classified as a protective membrane in a floor-ceiling or roof-ceiling assembly in accordance with the Standard ASTM E 119. All Firecode® protective membranes offered by USG have attained a Class A rating.

  • Does USG offer both types of ceiling panels — Class A and Firecode® branded panels?

    Yes. Some patterns are offered in both Class A and Firecode® branded formulations.

  • What is the difference between wet-felted and cast ceiling panels?

    Wet-felted panels are typically mechanically perforated and fissured. They are very dense and more economical than other types of ceiling panels. Cast ceiling panels are non-perforated and are manufactured in a different “cast” process, hence its name, that enhances their surface appearance and provides excellent sound absorption and durability.

  • Does the ceiling tile and grid system alone provide a fire-rated assembly?

    No. The ceiling system achieves a time rating based on the entire assembly which includes roof deck or floor deck assembly.

  • When hold-down clips are required, how much space should I leave between the clips, on the grid?

    The recommendation for hold-down clip spacing is two clips per panel, centered on the grid, between the panels.

  • How many acoustical panel types does USG offer?

    USG offers four major types of acoustical panels as well as Gypsum based panels for special applications. They are: Wet-Felted, Cast, "X" Technology and Fiberglass.

  • What is the best way to cut a reveal in a ceiling panel?

    The best way to cut a reveal edge in a panel is with a utility knife or a special Reveal edge tool.

  • How far in advance can I order ceiling panel before installation?

    Storage time of materials at the job site should be as short as possible, and environmental conditions should be as near as possible to those specified for occupancy. Excess humidity during storage can cause expansion of material and possible warp, sag, or poor fit after installation. Chemical changes in the mat and/or coatings can be aggravated by excess humidity and cause discoloration during storage, even in unopened cartons. Cartons should be removed from pallets and stringers to prevent distortion of material. Long-term (6-12 months) storage under uncontrolled environmental conditions should be avoided.

  • What is CAC?

    CAC stands for Ceiling Attenuation Class. It is the measure of the blocking of sound through one ceiling plane, into the plenum above, and back through the other ceiling plane to an adjacent space.

  • Why would I use one ceiling panel type over another?

    The different panel substrates provide panels with unique characteristics. The use of the different panels will vary based on specific needs and application.

  • Have a question?

    Let us do the research. We'll get back to you as quickly as we can.

    Ask USG
  • Need help right away?

    Call our Technical Support team at 800-874-4968 (Monday-Friday, 7:30 am - 4 pm Central).

Top