Sheetrock® Brand Mold Tough® Panels Firecode® C (UL Type C) are 1/2 in. (12.7 mm) enhanced proprietary Type X gypsum panels that feature a noncombustible, moisture-resistant gypsum core that is encased in moisture- and mold-resistant, 100% recycled green face and brown back papers. When tested in accordance with ASTM D3273, Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber, the panels meet or exceed ASTM C1396 specifications. The face paper is folded around the long edges to reinforce and protect the core, and the ends are cut square and even. The long edges of the panels are tapered, allowing joints to be reinforced and concealed with Sheetrock® Brand joint treatment systems. The panels are UL Classified for fire resistance and can be used in any UL Design in which Type C panels are listed. On the face along the long edge of each panel, the UL Type Designation is printed for easy identification by building inspectors.
Main Features
- 1/2 in. (12.7 mm) enhanced proprietary Type X panels with moisture and mold resistance for wall and ceiling applications
- Feature a noncombustible, moisture-resistant gypsum core encased in moisture- and mold-resistant, 100% recycled green face and brown back papers
- Comply with ASTM C1396, Standard Specification for Gypsum Board, for 1/2 in. (12.7 mm), Type X, water-resistant gypsum wallboard and exterior gypsum soffit board
- When tested in accordance with ASTM D3273, Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber, the panels meet or exceed ASTM C1396 specifications
- Underwriters Laboratories Inc. (UL) Classification as to fire resistance, surface-burning characteristics and noncombustibility
- Achieved GREENGUARD Gold Certification and qualifies as a low VOC emitting material (meets CA 01350)
Applications
- Administrative Offices
- Auditoriums and Gymnasiums
- Bars Restaurants and Dining Areas
- Cafeterias
- Classrooms
- Convention and Meeting Rooms
- Corridors and Hallways
- Department Stores and Boutiques
- Dormitories
- Executive Areas, Conference Areas and Board Rooms
- Exterior Soffits and Indoor Parking Garage
- Galleries and Exhibit Spaces
- Garages
- Grocery Stores
- Guest Rooms and Suites
- Health and Fitness
- Kitchens and Food Prep Areas
- Laboratories, Operating Rooms and Imaging Rooms
- Lobbies and Reception Areas
- Mall Interior Spaces
- Mechanical Rooms
- Media Centers, Music Rooms and Libraries
- Multi-Family Residential and Condos
- Nurseries and Birthing Rooms
- Open Plan Offices
- Patient Rooms
- Restrooms, Utility Rooms and Loading Docks
- Single-Family Residential
- Stairways and Elevator Shafts
- Theatres
- Traditional Offices
- Warehouses