Fine-textured panels. Superior sag resistance and sound control in an easy-to-install acoustical ceiling tile.

Explore Sizes & Options

Item: 76901

Acoustics: 0.70 NRC / 35 CAC

Size: 2 ft. x 4 ft.

Color: White

Standard Colors

Order a Sample

Overview

Overview

With ClimaPlus™ Performance
Superior sag resistance, outstanding dimensional stability, and available in high noise reduction coefficient (NRC) options these naturally fine textured and fast-installing panels are a viable product for many applications. Millennia® Acoustical Ceiling Panels are easy to install and clean, and their high level sag, mold and mildew resistance means they won't need to be replaced often. With excellent noise cancelling properties and durability, these panels are a sound, economical choice for any ceiling.

Sound Absorption

0.70 NRC

Sound Attenuation

35 CAC

Light Reflectance

Up To 0.85

Recycled Content

79 %

Main Features

Millennia® Acoustical Ceiling Panels are manufactured using a unique process that maximizes sound and anti-sag performance, producing excellent noise reduction coefficient (up to 0.75) and solid ceiling attenuation class (CAC) performance. They are an economic alternative to face-laminated panels while the non-directional pattern ensures consistent appearance, making these panels a reliable, long-term choice.
  • ClimaPlus™ 30-year lifetime system warranty against visible sag, mold and mildew
  • Available with High Recycled Content (HRC)
  • Low-emitting product meets CA Specification 01350, California Department of Health Services Standard Practice for the testing of VOC emissions

Applications

  • Administrative Offices
  • Bars Restaurants and Dining Areas
  • Classrooms
  • Department Stores and Boutiques
  • Executive Areas, Conference Areas and Board Rooms
  • Galleries and Exhibit Spaces
  • Lobbies and Reception Areas
  • Media Centers, Music Rooms and Libraries
  • Patient Rooms
  • Traditional Offices

Specifications

Data Sheet PDF 995.7 KB

Performance

  • Sound Absorption (NRC)
    NRC stands for Noise Reduction Coefficient. It is a measure of how much sound is absorbed by a given material. It is listed as a decimal and relates to percentage sound absorbed.
    0.70
  • Sound Attenuation (CAC) 35
  • Light Reflectance 0.85
  • Mold & Mildew Resistance Yes
  • Fire Resistance
    • Fire Rating Class A
  • ASTM E1264
    • astm-e1264-class III: Mineral base with painted finish, E: Lightly textured; G: Smooth, Form 1: Nodular; Form 2: Water-Felted
  • ASTM E84
    • Flame Spread 25 or less
    • Smoke Developed 50 or less
    • Fire Rating Class A

Sustainability

  • GREENGUARD Certification Yes
  • Recycled Content 79%
  • VOC Emissions Low-emitting

Physical Data

  • Thickness (in.) 3/4
  • Color White
  • Edge Fineline Bevel
  • Panel Size 2 ft. x 4 ft.
  • Material Mineral Fiber

Ask a question

Our customer support team will get back to you as soon as possible.

Question Guidlines

  • Questions should relate to this product specifically.
  • For help with pricing, availability, or delivery, please call 800.874.4968 (Monday–Friday, 7am–6pm Central)
  • All questions and answers follow USG’s Terms & Conditions.
  • Your question and USG’s answer may be posted to this page in the future, but none of your personal info will be included.

 Thanks for your message. We’ll be in touch!

q & a

  • Why is LR important?

    When the proper type of lighting fixture is used with a high LR ceiling, there can be savings in both initial construction costs as well as long-term energy costs. The concept is to use the ceiling to reflect light back into the occupied space.

  • Why is NRC important?

    NRC is very important in open office plan environments where there are few full height walls to help absorb or block sound.

  • What does ClimaPlus™ mean?

    USG’s line of products with ClimaPlus™ Performance have additional resistance to temperature and humidity. This in turn provides additional resistance to sagging and warping of the ceiling panels.

  • What does LR stand for?

    LR stands for light reflectance. It is a measure of the percentage of light which is reflected off of a given panel surface. Typically, the whiter and smoother the ceiling panel, the higher the LR value.

  • What is NRC?

    NRC stands for Noise Reduction Coefficient. It is a measure of how much sound is absorbed by a given material. It is listed as a decimal and relates to percentage sound absorbed.

  • When referring to ceiling panels, what is the meaning of type, form and pattern?

    These categories refer to ASTM Test E 1264.
    Type refers to the base material of the panel.
    Form refers to the manufacturing process of the panel.
    Pattern refers to the type of texture or pattern in the panel.

  • What is the difference between Class A and Firecode® branded materials?

    Class A signifies that a panel attained a flame spread index of 25 or less (based on 100 for untreated red oak) when tested in accordance with the Standard ASTM E 84. The Firecode® brand signifies that the panel has been classified as a protective membrane in a floor-ceiling or roof-ceiling assembly in accordance with the Standard ASTM E 119. All Firecode® protective membranes offered by USG have attained a Class A rating.

  • How many acoustical panel types does USG offer?

    USG offers four major types of acoustical panels as well as Gypsum based panels for special applications. They are: Wet-Felted, Cast, "X" Technology and Fiberglass.

  • What is the best way to cut a reveal in a ceiling panel?

    The best way to cut a reveal edge in a panel is with a utility knife or a special Reveal edge tool.

  • How far in advance can I order ceiling panel before installation?

    Storage time of materials at the job site should be as short as possible, and environmental conditions should be as near as possible to those specified for occupancy. Excess humidity during storage can cause expansion of material and possible warp, sag, or poor fit after installation. Chemical changes in the mat and/or coatings can be aggravated by excess humidity and cause discoloration during storage, even in unopened cartons. Cartons should be removed from pallets and stringers to prevent distortion of material. Long-term (6-12 months) storage under uncontrolled environmental conditions should be avoided.

  • What is the minimum NRC recommended for open office plan environments?

    It is best to use a minimum of .70 NRC and up to .80 - .90 NRC panel for this type of application.

  • What is "X" Technology?

    "X" Technology is a unique manufacturing method which was developed by and introduced to the market by USG in 1989. This technology is used to produce ceiling panels with sag resistance and exceptional acoustical performance found in USG’s line of ceiling products with ClimaPlus™ Performance.

  • What is CAC?

    CAC stands for Ceiling Attenuation Class. It is the measure of the blocking of sound through one ceiling plane, into the plenum above, and back through the other ceiling plane to an adjacent space.

  • Why would I use one ceiling panel type over another?

    The different panel substrates provide panels with unique characteristics. The use of the different panels will vary based on specific needs and application.

  • Have a question?

    Let us do the research. We'll get back to you as quickly as we can.

    Ask USG
  • Need help right away?

    Call our Technical Support team at 800-874-4968 (Monday-Friday, 7:30 am - 4 pm Central).

Top