It looks like you entered an employee email address, but this is the customer sign-in. Use the link below instead.

Item: 98245

Halcyon™ Acoustical Panels

Fine-textured panels with exeptional noise reduction for open-plan offices. Nondirectional, monolithic visual reduces installation time and waste.

Explore Sizes & Options

Item: 98245

Color:

Build a Submittal

Order a Sample

Overview

With ClimaPlus™ Performance
Fine-textured Halcyon™ Eco Acoustical Panels provide exceptional acoustical absorption and are built to last. Halcyon™ Eco Acoustical Panels are mold- and sag-resistant. Easy to install and clean, their noise reduction properties and high light reflectance values make these tiles perfect for open office plans as well as reception and lobby areas. Halcyon™ ECO Healthcare is manufactured with a plant-based binder and is part of the Ecoblueprint portfolio — meeting today’s sustainability standards.

Sound Absorption

0.95 NRC

Sound Attenuation

20 CAC

Light Reflectance

Up To 0.90

Recycled Content

40 %

Main Features

Halcyon™ Acoustical Panels are easy to maintain, and the foil backing on selected panels acts as a sound barrier that resists "breathing" (air passing through the surface), allowing them to stay cleaner longer. Additionally, these panels feature Inherent Performance which means that due to the fiberglass substrate these panels inherently resist the growth of mold and mildew.
  • Exceptional noise reduction with NRC values up to 1.00 and AC values up to 200 for open–plan offices.
  • High light reflective finish (LR-0.90) reduced light fixtures and energy use.
  • Washable and scrubbable finish.
  • Impact and scratch resistant.
  • Coordinates visually with Mars™ Acoustical Panels for open/closed-plan applications.
  • Compatible with Logix™ Integrated Ceiling Systems.
  • Nondirectional, monolithic visual reduces installation time and waste.
  • ClimaPlus™ 30-year lifetime system warranty against visible sag, mold and mildew.
  • Balanced Acoustics. High NRC & High CAC with backer options.
  • High postconsumer recycled content. Up to 42%.

Applications

  • Convention and Meeting Rooms
  • Department Stores and Boutiques
  • Executive Areas, Conference Areas and Board Rooms
  • Galleries and Exhibit Spaces
  • Lobbies and Reception Areas
  • Mall Interior Spaces
  • Media Centers, Music Rooms and Libraries
  • Open Plan Offices

Specifications

Submittal Sheet

Performance

  • Sound Absorption (NRC)
    NRC stands for Noise Reduction Coefficient. It is a measure of how much sound is absorbed by a given material. It is listed as a decimal and relates to percentage sound absorbed.
    0.95
  • Sound Attenuation (CAC) 20
  • Light Reflectance 0.90
  • Mold & Mildew Resistance
    Contains a broad-spectrum antimicrobial additive on the face and back of the panel that provides resistance against the growth of mold and mildew. Includes sag-resistance performance.
    Yes
  • Fire Resistance
    • Fire Rating Class A
  • ASTM E1264
    • astm-e1264-class XII: Glass fiber base with membrane-faced overlay, E: Lightly textured; G: Smooth, Form 2: Water-Felted
  • ASTM E84
    • Flame Spread 25 or less
    • Smoke Developed 50 or less
    • Fire Rating Class A

Sustainability

  • Recycled Content 40%

Physical Data

  • Thickness (in.) 1
  • Edge Fineline
  • Panel Size 2' x 4'

Installation

Installation Guide PDF 677.1 KB

USG Ceilings Portfolio Series: Episode 1 - Installation & Edge Style

It is important to consider which installation method and edge style is right for your project. This video details the options you have when using USG products.

USG Ceilings Portfolio Series: Episode 2 - Performance Features

Consider these performance attributes when choosing your ceiling.

USG Ceilings Portfolio Series: Episode 3 - USG Panel Types

Each of USG's ceiling panels offers a solution for its unique environment.

Documents & Files

Installation & Technical Manuals

Technical Guide (English)
Installation Guide (English) PDF 677.1 KB

SDS, Certifications & Reports

SDS (English) PDF 161.1 KB
SDS (Spanish) PDF 180.1 KB

Warranties

Warranties (English) PDF 611.0 KB

Sustainability

EPD (English) PDF 682.9 KB

Ask a question

Our customer support team will get back to you within 48 hours

Question Guidlines

  • Questions should relate to this product specifically.
  • For help with pricing, availability, or delivery, please call 800.874.4968 (Monday–Friday, 7am–6pm Central)
  • All questions and answers follow USG’s Terms & Conditions.
  • Your question and USG’s answer may be posted to this page in the future, but none of your personal info will be included.

q & a

  • How many acoustical panel types does USG offer?

    USG offers four major types of acoustical panels as well as Gypsum based panels for special applications. They are: Wet-Felted, Cast, "X" Technology and Fiberglass.

  • Why is NRC important?

    NRC is very important in open office plan environments where there are few full height walls to help absorb or block sound.

  • Why is LR important?

    When the proper type of lighting fixture is used with a high LR ceiling, there can be savings in both initial construction costs as well as long-term energy costs. The concept is to use the ceiling to reflect light back into the occupied space.

  • What does ClimaPlus™ mean?

    USG’s line of products with ClimaPlus™ Performance have additional resistance to temperature and humidity. This in turn provides additional resistance to sagging and warping of the ceiling panels.

  • What does LR stand for?

    LR stands for light reflectance. It is a measure of the percentage of light which is reflected off of a given panel surface. Typically, the whiter and smoother the ceiling panel, the higher the LR value.

  • What is NRC?

    NRC stands for Noise Reduction Coefficient. It is a measure of how much sound is absorbed by a given material. It is listed as a decimal and relates to percentage sound absorbed.

  • When referring to ceiling panels, what is the meaning of type, form and pattern?

    These categories refer to ASTM Test E 1264.
    Type refers to the base material of the panel.
    Form refers to the manufacturing process of the panel.
    Pattern refers to the type of texture or pattern in the panel.

  • What is the difference between Class A and Firecode® branded materials?

    Class A signifies that a panel attained a flame spread index of 25 or less (based on 100 for untreated red oak) when tested in accordance with the Standard ASTM E 84. The Firecode® brand signifies that the panel has been classified as a protective membrane in a floor-ceiling or roof-ceiling assembly in accordance with the Standard ASTM E 119. All Firecode® protective membranes offered by USG have attained a Class A rating.

  • What is the best way to cut a reveal in a ceiling panel?

    The best way to cut a reveal edge in a panel is with a utility knife or a special Reveal edge tool.

  • How far in advance can I order ceiling panel before installation?

    Storage time of materials at the job site should be as short as possible, and environmental conditions should be as near as possible to those specified for occupancy. Excess humidity during storage can cause expansion of material and possible warp, sag, or poor fit after installation. Chemical changes in the mat and/or coatings can be aggravated by excess humidity and cause discoloration during storage, even in unopened cartons. Cartons should be removed from pallets and stringers to prevent distortion of material. Long-term (6-12 months) storage under uncontrolled environmental conditions should be avoided.

  • What is the minimum NRC recommended for open office plan environments?

    It is best to use a minimum of .70 NRC and up to .80 - .90 NRC panel for this type of application.

  • What is CAC?

    CAC stands for Ceiling Attenuation Class. It is the measure of the blocking of sound through one ceiling plane, into the plenum above, and back through the other ceiling plane to an adjacent space.

  • Why would I use one ceiling panel type over another?

    The different panel substrates provide panels with unique characteristics. The use of the different panels will vary based on specific needs and application.

  • Have a question?

    Let us do research and get back to you (usually within 48 hours).

    Ask USG
  • Need help right away?

    Call our Technical Support team at 800-874-4968 (Monday-Friday, 7am-6pm Central).

Top