Changer votre pays / région

It looks like you entered an employee email address, but this is the customer sign-in. Use the link below instead.

UL U493

Chase Wall - Steel Stud (Non-Load-Bearing)

Indice de résistance au feu 1 heures
Système ITS (STC) 60
Épaisseur du système 240.8 mm

CAD / Revit & Acoustique

Assemblage de Construction

Assemblage de Construction

Layer 1 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® Gypsum Panel (UL Type SCX)

Layer 2 - Steel Studs:

1 layer 3-5/8" [92 mm] steel studs, EQ20 (0.018"), staggered, 16" [406 mm] O.C.

Layer 3 - Insulation:

1 layer 3-1/2" [89 mm] Fiberglass insulation

Layer 4 - Air Space:

1 layer 1" [25.4 mm] air space

Layer 5 - Steel Studs:

1 layer 3-5/8" [92 mm] steel studs, EQ20 (0.018"), staggered, 16" [406 mm] O.C.

Layer 6 - Insulation:

1 layer 3-1/2" [89 mm] Fiberglass insulation

Layer 7 - Gypsum Panel:

1 layer 5/8" [15.9 mm] Sheetrock® Gypsum Panel (UL Type SCX)

Notes